Sign In | Join Free | My polstate.com |
|
Brand Name : SIEMENS
Model Number : 6ES7516-3FN02-0AB0
Certification : CE
Place of Origin : Germany
MOQ : 1
Price : USD
Payment Terms : L/C, T/T
Supply Ability : 100
Delivery Time : 10-12Days
Packaging Details : 15,10 x 15,40 x 4,60
Weight : 0.8 kg
Number Of Analog Outputs : Up to 32
Number Of Digital Outputs : Up to 64
Protection Rating : IP20
Operating Temperature : -25 to 60 degrees Celsius
Number Of Analog Inputs : Up to 32
Number Of Digital Inputs : Up to 64
Certifications : CE, UL, cUL, FM, ATEX, KC
Communication Interfaces : PROFINET, PROFIBUS, Ethernet/IP, Modbus TCP, OPC UA
Programming Languages : Ladder Logic, Function Block Diagram, Structured Control Language, SCL
Dimensions : 130 x 125 x 125 mm
Power Supply : 24 V DC
Memory : Up to 2 MB
Cpu Type : S7-1500
SIEMENS 6ES7516-3FN02-0AB0 PROFINET IRT WITH 2-PORT SWITCH, 25 NS BIT PERFORMANCE, INCLUDING PUSH-IN FRONT CONNECTOR
The SIEMENS 6ES7516-3FN02-0AB0 is a PROFINET IRT controller module with a built-in 2-port switch, designed for use in SIMATIC S7-1500 automation systems. Here are the key details about this product:
Product Description:
- The 6ES7516-3FN02-0AB0 is a PROFINET IRT (Isochronous Real-Time) CPU module.
- It provides high-performance PROFINET connectivity with a 2-port Ethernet switch.
- Enables deterministic and time-synchronized PROFINET communication.
- Suitable for applications requiring precise motion control and real-time data exchange.
Key Features:
- PROFINET IRT with 25ns bit performance for high-speed data transmission.
- Integrated 2-port switch for flexible network topologies.
- Supports PROFINET device communication and I-Device functionality.
- Includes push-in style front connector for easy wiring.
- Powerful CPU with 1.5 MB work memory and 5 MB load memory.
Connectivity:
- 2 x PROFINET ports with integrated 2-port switch.
- Supports ring, star, and linear network topologies.
- Enables direct connection of PROFINET devices.
Performance:
- 25ns bit performance for precise and deterministic PROFINET IRT communication.
- Suitable for time-critical motion control and manufacturing applications.
Front Connector:
- Push-in style front connector for simple and tool-free wiring.
- Simplifies installation and reduces configuration time.
Other Details:
- Part of the SIMATIC S7-1500 controller family.
- Designed for high-speed, real-time industrial Ethernet applications.
- Provides advanced features for automation and motion control.
- Supports extensive diagnostic and maintenance functions.
In summary, the SIEMENS 6ES7516-3FN02-0AB0 is a high-performance PROFINET IRT controller module with a 2-port switch and 25ns bit performance, offering deterministic real-time communication for SIMATIC S7-1500 automation systems.
General information | ||
Product type designation | CPU 1516F-3 PN/DP | |
HW functional status | FS01 | |
Firmware version | V2.9 | |
Product function | ||
● I&M data | Yes; I&M0 to I&M3 | |
● Isochronous mode | Yes; Distributed and central; with minimum OB 6x cycle of 375 µs (distributed) and 1 ms (central) | |
Engineering with | ||
● STEP 7 TIA Portal configurable/integrated from version | V17 (FW V2.9) / V16 (FW V2.8) or higher; with older TIA Portal versions configurable as 6ES7516-3FN01-0AB0 | |
Configuration control | ||
via dataset | Yes | |
Display | ||
Screen diagonal [cm] | 6.1 cm | |
Control elements | ||
Number of keys | 8 | |
Mode buttons | 2 | |
Supply voltage | ||
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | |
Reverse polarity protection | Yes | |
Mains buffering | ||
● Mains/voltage failure stored energy time | 5 ms | |
Input current | ||
Current consumption (rated value) | 0.85 A | |
Current consumption, max. | 1.1 A | |
Inrush current, max. | 2.4 A; Rated value | |
I²t | 0.02 A²·s | |
Power | ||
Infeed power to the backplane bus | 12 W | |
Power consumption from the backplane bus (balanced) | 6.7 W | |
Power loss | ||
Power loss, typ. | 7 W | |
Memory | ||
Number of slots for SIMATIC memory card | 1 | |
SIMATIC memory card required | Yes | |
Work memory | ||
● integrated (for program) | 1.5 Mbyte | |
● integrated (for data) | 5 Mbyte | |
Load memory | ||
● Plug-in (SIMATIC Memory Card), max. | 32 Gbyte | |
Backup | ||
● maintenance-free | Yes | |
CPU processing times | ||
for bit operations, typ. | 10 ns | |
for word operations, typ. | 12 ns | |
for fixed point arithmetic, typ. | 16 ns | |
for floating point arithmetic, typ. | 64 ns | |
CPU-blocks | ||
Number of elements (total) | 8 000; Blocks (OB, FB, FC, DB) and UDTs | |
DB | ||
● Number range | 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 | |
● Size, max. | 5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB | |
FB | ||
● Number range | 0 ... 65 535 | |
● Size, max. | 1 Mbyte | |
FC | ||
● Number range | 0 ... 65 535 | |
● Size, max. | 1 Mbyte | |
OB | ||
● Size, max. | 1 Mbyte | |
● Number of free cycle OBs | 100 | |
● Number of time alarm OBs | 20 | |
● Number of delay alarm OBs | 20 | |
● Number of cyclic interrupt OBs | 20; With minimum OB 3x cycle of 250 µs | |
● Number of process alarm OBs | 50 | |
● Number of DPV1 alarm OBs | 3 | |
● Number of isochronous mode OBs | 3 | |
● Number of technology synchronous alarm OBs | 2 | |
● Number of startup OBs | 100 | |
● Number of asynchronous error OBs | 4 | |
● Number of synchronous error OBs | 2 | |
● Number of diagnostic alarm OBs | 1 | |
Nesting depth | ||
● per priority class | 24; Up to 8 possible for F-blocks | |
Counters, timers and their retentivity | ||
S7 counter | ||
● Number | 2 048 | |
Retentivity | ||
— adjustable | Yes | |
IEC counter | ||
● Number | Any (only limited by the main memory) | |
Retentivity | ||
— adjustable | Yes | |
S7 times | ||
● Number | 2 048 | |
Retentivity | ||
— adjustable | Yes | |
IEC timer | ||
● Number | Any (only limited by the main memory) | |
Retentivity | ||
— adjustable | Yes | |
Data areas and their retentivity | ||
Retentive data area (incl. timers, counters, flags), max. | 512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB | |
Extended retentive data area (incl. timers, counters, flags), max. | 5 Mbyte; When using PS 6 0W 24/48/60 V DC HF | |
Flag | ||
● Size, max. | 16 kbyte | |
● Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte | |
Data blocks | ||
● Retentivity adjustable | Yes | |
● Retentivity preset | No | |
Local data | ||
● per priority class, max. | 64 kbyte; max. 16 KB per block | |
Address area | ||
Number of IO modules | 8 192; max. number of modules / submodules | |
I/O address area | ||
● Inputs | 32 kbyte; All inputs are in the process image | |
● Outputs | 32 kbyte; All outputs are in the process image | |
per integrated IO subsystem | ||
— Inputs (volume) | 8 kbyte | |
— Outputs (volume) | 8 kbyte | |
per CM/CP | ||
— Inputs (volume) | 8 kbyte | |
— Outputs (volume) | 8 kbyte | |
Subprocess images | ||
● Number of subprocess images, max. | 32 | |
Hardware configuration | ||
Number of distributed IO systems | 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link) | |
Number of DP masters | ||
● integrated | 1 | |
● Via CM | 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total | |
Number of IO Controllers | ||
● integrated | 2 | |
● Via CM | 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total | |
Rack | ||
● Modules per rack, max. | 32; CPU + 31 modules | |
PtP CM | ||
● Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots | |
Time of day | ||
Clock | ||
● Type | Hardware clock | |
● Backup time | 6 wk; At 40 °C ambient temperature, typically | |
● Deviation per day, max. | 10 s; Typ.: 2 s | |
Operating hours counter | ||
● Number | 16 | |
Clock synchronization | ||
● supported | Yes | |
● to DP, master | Yes | |
● in AS, master | Yes | |
● in AS, slave | Yes | |
● on Ethernet via NTP | Yes | |
Interfaces | ||
Number of PROFINET interfaces | 2 | |
Number of PROFIBUS interfaces | 1 | |
1. Interface | ||
Interface types | ||
● RJ 45 (Ethernet) | Yes; X1 | |
● Number of ports | 2 | |
● integrated switch | Yes | |
Protocols | ||
● IP protocol | Yes; IPv4 | |
● PROFINET IO Controller | Yes | |
● PROFINET IO Device | Yes | |
● SIMATIC communication | Yes | |
● Open IE communication | Yes; Optionally also encrypted | |
● Web server | Yes | |
● Media redundancy | Yes; MRP Automanager according to IEC 62439-2 Edition 2.0 | |
PROFINET IO Controller | ||
Services | ||
— PG/OP communication | Yes | |
— Isochronous mode | Yes | |
— Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) | |
— IRT | Yes | |
— PROFIenergy | Yes; per user program | |
— Prioritized startup | Yes; Max. 32 PROFINET devices | |
— Number of connectable IO Devices, max. | 256; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET | |
— Of which IO devices with IRT, max. | 64 | |
— Number of connectable IO Devices for RT, max. | 256 | |
— of which in line, max. | 256 | |
— Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces | |
— Number of IO Devices per tool, max. | 8 | |
— Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data | |
Update time for IRT | ||
— for send cycle of 250 µs | 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 375 µs of the isochronous OB is decisive | |
— for send cycle of 500 µs | 500 µs to 8 ms | |
— for send cycle of 1 ms | 1 ms to 16 ms | |
— for send cycle of 2 ms | 2 ms to 32 ms | |
— for send cycle of 4 ms | 4 ms to 64 ms | |
— With IRT and parameterization of "odd" send cycles | Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs) | |
Update time for RT | ||
— for send cycle of 250 µs | 250 µs to 128 ms | |
— for send cycle of 500 µs | 500 µs to 256 ms | |
— for send cycle of 1 ms | 1 ms to 512 ms | |
— for send cycle of 2 ms | 2 ms to 512 ms | |
— for send cycle of 4 ms | 4 ms to 512 ms | |
PROFINET IO Device | ||
Services | ||
— PG/OP communication | Yes | |
— Isochronous mode | No | |
— IRT | Yes | |
— PROFIenergy | Yes; per user program | |
— Shared device | Yes | |
— Number of IO Controllers with shared device, max. | 4 | |
— activation/deactivation of I-devices | Yes; per user program | |
— Asset management record | Yes; per user program |
![]() |
SIEMENS 6ES7516-3FN02-0AB0 PROFINET IRT WITH 2-PORT SWITCH, 25 NS BIT PERFORMANCE, INCLUDING PUSH-IN FRONT CONNECTOR Images |