Brand Name : SIEMENS

Model Number : 6ES7516-3UN00-0AB0

Certification : CE

Place of Origin : Germany

MOQ : 1

Price : USD

Payment Terms : L/C, T/T

Supply Ability : 100

Delivery Time : 10-12Days

Packaging Details : 15,10 x 15,40 x 4,60

Number Of Analog Outputs : Up to 32

Product Type : PLC

Memory : Up to 1 MB

Cpu Type : S7-1500

Number Of Digital Outputs : Up to 512

Number Of Analog Inputs : Up to 32

Number Of Digital Inputs : Up to 512

Operating Temperature : -25°C to +60°C

Certifications : CE, UL, CSA, FM, CCC, KC

Dimensions : Standard: 100 x 125 x 75 mm, Compact: 80 x 125 x 75 mm

Weight : Standard: 0.5 kg, Compact: 0.4 kg

Communication Interfaces : Profinet, Profibus, Ethernet/IP, Modbus TCP, OPC UA

Programming Languages : Ladder Logic, Function Block Diagram, Structured Text, SCL

Power Supply : 24V DC

Contact Now

SIEMENS 6ES7516-3UN00-0AB0 PROFINET IRT WITH 2-PORT SWITCH, 2ND INTERFACE, ETHERNET, 3RD INTERFACE, PROFIBUS

Understood. Here are the key details about the SIEMENS 6ES7516-3UN00-0AB0 PROFINET IRT controller module:

Product Description:
- The 6ES7516-3UN00-0AB0 is a SIMATIC S7-1500 CPU module with advanced PROFINET and PROFIBUS connectivity.
- It features an integrated 2-port PROFINET IRT (Isochronous Real-Time) switch.
- Additionally, it provides a second Ethernet interface and a third PROFIBUS interface.

Key Features:
- PROFINET IRT (Isochronous Real-Time) support for deterministic communication
- Integrated 2-port PROFINET switch for flexible network topologies
- Second Ethernet interface for additional Ethernet-based communication
- Third interface for PROFIBUS master or slave functionality
- Powerful CPU with 2 MB work memory and 10 MB load memory
- Supports PROFINET device and I-Device functionality

Connectivity:
- 2 x PROFINET ports with integrated 2-port switch
- 1 x additional Ethernet interface
- 1 x PROFIBUS interface

Performance:
- High-speed PROFINET IRT communication with deterministic real-time capabilities
- Suitable for applications requiring precise motion control and synchronized data exchange

Certifications:
- According to the information available, the 6ES7516-3UN00-0AB0 module likely has relevant industrial certifications and approvals, such as:
- IEC 61131-2 (Programmable controllers)
- UL Recognized Component marking
- Hazardous Locations approvals (e.g., Class I, Division 2)
- Marine classification society approvals

Overall, the SIEMENS 6ES7516-3UN00-0AB0 is a versatile PROFINET IRT controller module that provides advanced connectivity options, including PROFINET, Ethernet, and PROFIBUS, making it suitable for a wide range of industrial automation applications.

General information
Product type designation CPU 1516TF-3 PN/DP
HW functional status FS11
Firmware version V3.1
● FW update possible Yes
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode Yes; Distributed and central; with minimum OB 6x cycle of 375 µs (distributed) and 1 ms (central)
● SysLog Yes
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V19 (FW V3.1) / V15 (FW V2.5) or higher
Configuration control
via dataset Yes
Display
Screen diagonal [cm] 6.1 cm
Control elements
Number of keys 6
Mode selector switch 1
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering
● Mains/voltage failure stored energy time 5 ms
Input current
Current consumption (rated value) 1.2 A
Current consumption, max. 1.5 A
Inrush current, max. 1.9 A; Rated value
I²t 0.4 A²·s
Power
Infeed power to the backplane bus 12 W
Power consumption from the backplane bus (balanced) 30 W
Power loss
Power loss, typ. 24 W
Memory
Number of slots for SIMATIC memory card 1
SIMATIC memory card required Yes
Work memory
● integrated (for program) 3 Mbyte
● integrated (for data) 7.5 Mbyte
Load memory
● Plug-in (SIMATIC Memory Card), max. 32 Gbyte
Backup
● maintenance-free Yes
CPU processing times
for bit operations, typ. 6 ns
for word operations, typ. 7 ns
for fixed point arithmetic, typ. 9 ns
for floating point arithmetic, typ. 37 ns
CPU-blocks
Number of elements (total) 8 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number range 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
● Size, max. 7.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
● Number range 0 ... 65 535
● Size, max. 1 Mbyte
FC
● Number range 0 ... 65 535
● Size, max. 1 Mbyte
OB
● Size, max. 1 Mbyte
● Number of free cycle OBs 100
● Number of time alarm OBs 20
● Number of delay alarm OBs 20
● Number of cyclic interrupt OBs 20; With minimum OB 3x cycle of 250 µs
● Number of process alarm OBs 50
● Number of DPV1 alarm OBs 3
● Number of isochronous mode OBs 3
● Number of technology synchronous alarm OBs 2
● Number of startup OBs 100
● Number of asynchronous error OBs 4
● Number of synchronous error OBs 2
● Number of diagnostic alarm OBs 1
Nesting depth
● per priority class 24; Up to 8 possible for F-blocks
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— adjustable Yes
IEC counter
● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes
S7 times
● Number 2 048
Retentivity
— adjustable Yes
IEC timer
● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB
Extended retentive data area (incl. timers, counters, flags), max. 7.5 Mbyte; When using PS 6 0W 24/48/60 V DC HF
Flag
● Size, max. 16 kbyte
● Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
● Retentivity adjustable Yes
● Retentivity preset No
Local data
● per priority class, max. 64 kbyte; max. 16 KB per block
Address area
Number of IO modules 8 192; max. number of modules / submodules
I/O address area
● Inputs 32 kbyte; All inputs are in the process image
● Outputs 32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume) 8 kbyte
— Outputs (volume) 8 kbyte
per CM/CP
— Inputs (volume) 8 kbyte
— Outputs (volume) 8 kbyte
Subprocess images
● Number of subprocess images, max. 32
Hardware configuration
Number of distributed IO systems 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Number of DP masters
● integrated 1
● Via CM 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Number of IO Controllers
● integrated 2
● Via CM 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Rack
● Modules per rack, max. 32; CPU + 31 modules
PtP CM
● Number of PtP CMs the number of connectable PtP CMs is only limited by the number of available slots
Time of day
Clock
● Type Hardware clock
● Backup time 6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max. 10 s; Typ.: 2 s
Operating hours counter
● Number 16
Clock synchronization
● supported Yes
● to DP, master Yes
● to DP, slave Yes
● in AS, master Yes
● in AS, slave Yes
● on Ethernet via NTP Yes
Interfaces
Number of PROFINET interfaces 2
Number of PROFIBUS interfaces 1
1. Interface
Interface types
● RJ 45 (Ethernet) Yes; X1
● Number of ports 2
● integrated switch Yes
Protocols
● IP protocol Yes; IPv4
● PROFINET IO Controller Yes
● PROFINET IO Device Yes
● SIMATIC communication Yes
● Open IE communication Yes; Optionally also encrypted
● Web server Yes
● Media redundancy Yes
PROFINET IO Controller
Services
— Isochronous mode Yes
— Direct data exchange Yes; Requirement: IRT and isochronous mode (MRPD optional)
— IRT Yes
— PROFIenergy Yes; per user program
— Prioritized startup Yes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max. 256; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Of which IO devices with IRT, max. 64
— Number of connectable IO Devices for RT, max. 256
— of which in line, max. 256
— Number of IO Devices that can be simultaneously activated/deactivated, max. 8; in total across all interfaces
— Number of IO Devices per tool, max. 8
— Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
— PROFINET Security Class 1
Update time for IRT
— for send cycle of 250 µs 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 375 µs of the isochronous OB is decisive
— for send cycle of 500 µs 500 µs to 8 ms
— for send cycle of 1 ms 1 ms to 16 ms
— for send cycle of 2 ms 2 ms to 32 ms
— for send cycle of 4 ms 4 ms to 64 ms
— With IRT and parameterization of "odd" send cycles Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
Update time for RT
— for send cycle of 250 µs 250 µs to 128 ms
— for send cycle of 500 µs 500 µs to 256 ms
— for send cycle of 1 ms 1 ms to 512 ms
— for send cycle of 2 ms 2 ms to 512 ms
— for send cycle of 4 ms 4 ms to 512 ms
PROFINET IO Device

SIEMENS 6ES7516-3UN00-0AB0 PROFINET IRT WITH 2-PORT SWITCH, 2ND INTERFACE, ETHERNET, 3RD INTERFACE, PROFIBUS


Wholesale SIEMENS 6ES7516-3UN00-0AB0 PROFINET IRT WITH 2-PORT SWITCH, 2ND INTERFACE, ETHERNET, 3RD INTERFACE, PROFIBUS from china suppliers

SIEMENS 6ES7516-3UN00-0AB0 PROFINET IRT WITH 2-PORT SWITCH, 2ND INTERFACE, ETHERNET, 3RD INTERFACE, PROFIBUS Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Voboal Industrial Automation Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)